Surplus Optical, Scientific, and Electronic Test and Measurement Equipment
    new arrivals  |  site map  | requests  |  policies  |  about us  |  contact us    search 
Tektronix TV1350 Television Demodulator

Tektronix TV1350 Television Demodulator
 Features
  • Continuously Tunable Over All TV Bands and CATV Channels (HRC and IRC) to 880 MHz (Channels 2-99)
  • Automatic Compensation for Carrier Offsets to ±100 kHz
  • Switch Selectable Sound Trap
  • Switchable IF Gain for Improved S/N Ratio
  • Selectable Envelope or Synchronous Detection
  • Synchronous Detector Quadrature Output
  • Stable Zero Carrier Reference for Video Level Adjustments and Residual Carrier Measurements
  • Parallel Remote Control Interface and IEEE-488 (GPIB) Option Included

 Available Stock Items and Accessory Choices
Tektronix TV1350 Television Demodulator
Tektronix TV1350 Television Demodulator

This Tektronix TV1350 Television Demodulator is used and in excellent condition.

Installed options: Standard M and GPIB Interface.
Version: 1.1
Stock #: 43444-1
In Stock: 2
Price:Contact Us
Instraview Request Quote Request

 Description
The TV1350 family is capable of solving all problems in the field of TV reception and demodulation.

The Tektronix TV1350 Television Demodulator provides an accurate link between RF signals and baseband measuring equipment. It captures and demodulates TV signals with true fidelity and full transparency and is ideal for monitoring testing and adjustment applications in both TV transmitter and CATV systems.

Synthesizer frequency processing provides continuous coverage of all TV bands and cable channels. Channel selection is simply a matter of entering the channel number manually from the front panel or via the remote interface. A search mode facilitates automatic tuning. Accuracy is < 2.5 kHz and carrier offsets to ±100 kHz are compensated automatically.

Up to 20 dB of built-in RF attenuation is selectable, either manually or automatically. The RF input level is indicated on an analog meter, with the optimal input level marked directly on the meter. Highly effective adjacent channel suppression is provided by a SAW filter.

The TV1350 offers user-selectable envelope or synchronous detection. Two isolated video outputs and two quadrature signal outputs facilitate convenient measurement of incidental phase modulation of the video carrier to determine the intercarrier S/N ratio of the sound channel. The quadrature signal output is especially suited for adjustment of linearity and phase equalizing circuits in TV transmitters. A stable zero carrier reference enables accurate measurement of the video modulation depth.

Frequency deviation of the sound carrier can be measured on the front panel analog meter. Narrow, wideband, mono and stereo BTSC audio outputs are available. Complex audio processing circuits maintain equal deviation of the two audio demodulators to ensure low stereo crosstalk. A built-in loudspeaker with a volume control and a headphone jack provide convenient monitoring of the audio signal. Parallel remote control capability is standard. An IEEE-488 (GPIB) bus interface is optional.

Key Features Common to the TV1350 Products Are:
Two isolated video outputs
Two quadrature outputs for ICPM measurements
Zero carrier reference pulse
Switchover from synchronous to envelope detection
Channel selection with digital entry of channel number either in manual or in remote mode
Automatic control of frequency offset up to ±100 kHz
Continuously tunable in all TV bands, also in special channels from 54 MHz to 880 MHz
SAW filter switch-selected on front panel for adjacent channel suppression
Optional GPIB control (IEC 625-1/IEEE 488), thus channel selection also possible by entering the vision carrier frequency
Reduction of IF gain allowing operation at high input levels (demodulator mode) and thus providing increased video S/N ratio.


Product Family: TV1350, TV-1350, TV 1350, 1350


Notice - All items included are listed or displayed above.


 Technical Specifications
Frequency RangeBands I, II, III, IV/V, cable channels from 54
to 880 MHz for HRC or IRC, 38.9 MHz and
45.75 MHz IF
Channel SelectionManual or remote entry of channel number,
automatic search or IEEE-488 bus.
Frequency ProcessingBy synthesizer
Frequency Error≤ ±2.5 kHz
≤ ±30 kHz (AFC)
Inputs
RFType N female, 50 Ohm
RFBNC female, 50 and 75 Ohm
IFBNC female
Input Voltage Range
RF.25 to 30 mV
.5 to 100 mV, switchable
IF5 to 100 mV
Return Loss
IF>20 dB
50 Ohm, RF>12 dB, <300 MHz;
>10 dB, >300 MHz
75 Ohm, RF>8 dB
RF Input Attenuation0/10/20 dB, automatic or
manual adjustment
Noise Figure<9 dB, VHF; <12 dB, UHF
Video Channel
Non-Linearity≤ 2% differential gain,
≤ 2° differential phase,
10 to 75% modulation depth, synchronous detection
Chrominance / Luminance Delay≤ ±20 ns (via IF input 1)
≤ ±25 ns (w/o SAW filter). Additional ripple of SAW filter
≤ ±50 ns
Tilt (50 Hz)≤ 0.5%
Gain Control Automatic or manual,
> 34 dB dynamic range,
typ. 40 dB,
plus 2 x 10 dB input attenuation for TV1350
Audio Channel
Intercarrier Frequency4.5 MHz
Intercarrier S/N≥ 46 dB 0-4 MHz, sine modulation;
≥ 52 dB without vision modulation
Frequency Response≤ ±0.5 dB flatness, referred to 50 µs de-emphasis
Harmonic Distortion≤ 1%, typ. 0.5%, at ±50 kHz deviation and 5 kHz modulation frequency
Stereo Crosstalk Down ≥ 36 dB
Channel Crosstalk Down ≥ 70 dB
Outputs
Video In-phase1 Vp-p, CVS with standard modulation;
75 Ohm;
BNC front and rear panel connectors
Video Quadrature1 Vp-p with standard modulation and 90° phase shift of switching carrier;
75 Ohm;
BNC front and rear panel connectors
IF Output200 mV rms ±3 dB;
50 Ohm;
BNC rear panel connector
Audio Output+6 dBm ±0.5 dB, with ±30 kHz deviation and 500 Hz modulation frequency
Front Panel Indication
Analog MeterInput level with marking of optimal level range; deviation of sound (50 kHz and 100 kHz fsd); marker for correct video output level
LEDsSelected channel, no video carrier, no sound carrier, no pilot and stereo
Zero Reference PulseFor checking of residual carrier, field-repetitive, can be enabled in lines 15 to 328 (factory-set) of field blanking interval or triggered by external pulse
Error Referred to CVS in Case of Synchronous Detection≤ 1.5%
LoudspeakerFront panel volume control
Power Supply110/120/220/240 V AC ±10%, 47-63 Hz
Temperature Rated+40°F to +115°F (+5°C to +46°C).
Operating: +32°F to +115°F (0°C to +46°C).
Nonoperating: -40°F to +158°F (-40°C to +70°C)


 Pictures
  Click on pictures below for larger image:

Tektronix TV1350 Television Demodulator
Tektronix TV1350 Television Demodulator


 Resources - Manuals, Datasheets, Drivers, Links
  Click on links below for more information:






  Customer Support
Courteous, Knowledgeable Customer Support
Email us today!
We Securely Accept:
We Securely Accept VISA MasterCard American Express Discover
  Guarantee
Artisan Scientific Offers a 30-Day Return Guarantee and a minimum 90-Day Warranty!
Read our full


90-Day Warranty



Site Map | About Us | Contact Us | Home | Login
301 E. Mercury Drive   Champaign, IL 61822
888-887-6872 | 217-352-9330

Copyright © 1999-2008 Artisan Scientific Corporation
All rights reserved. All logos and trademarks are properties of their respective companies.
Product price, specification, warranty and availability subject to change without notice.
Valid XHTML 1.0 Transitional